Deep Drawn Parts for Electrical & Electronic Enclosures

Drawn motor cans, end caps, capacitor and battery cases, shielding cans and junction-box covers — in steel, aluminium and stainless steel.

Electrical parts are made in numbers. A drawn can or cover has to hit tolerance every time across a run of hundreds of thousands, keep a plating that will not flake, and cost what the bill of materials allows. We run these parts on progressive and single-station presses with automated tapping and assembly in line, and control burrs, roundness and flatness at the press. Because we draw, machine and finish under one roof, the part you approve in the sample report is the part we ship at volume.

The difficult geometry in electrical work is usually concentricity — a motor can whose bore and end face must run true, or a shield that has to seat squarely in an assembly. We hold those features at the draw and the secondary operation, then verify them on the CMM and 2D vision system before packing.

How We Draw for Electrical & Electronics

Motor cans and end caps drawn at Aunov
Motor Cans & End Caps

Seamless cans drawn with concentric bores and end faces that must run true.

Progressive-die volume at Aunov
Progressive-Die Volume

High-speed progressive lines hold tolerance across millions of pieces per year.

Plating-ready electrical parts inspected at Aunov
Plating-Ready & Inspected

Burr-controlled, plating-ready parts, checked on CMM and 2D vision before packing.

At a glance
✓Materials — SPCC / galvanised steel, aluminium, SUS304, copper and brass
✓Thickness — 0.15 mm to 3.0 mm
✓Draw capability — diameters to 300 mm, depth-to-diameter beyond 2:1
✓Tolerances — ±0.01 to ±0.05 mm
✓Finishing — zinc / nickel / tin plating, powder coat and painting
✓Volume — prototype through multi-million pieces per year

Electrical & Electronic Parts We Make

Also drawn for electrical and electronics: capacitor and battery cans, shielding cans, lamp holders, terminal cups and heat-sink enclosures.

Materials & Finishes

SPCC and galvanised steel for plated cases and covers; aluminium for light, thermally active housings; SUS304 for corrosion resistance; copper and brass for contacts and small drawn bodies. Parts are supplied ready for zinc, nickel or tin plating, powder coating and painting, with automated tapping and assembly available in line.

Enclosure Types We Draw

Electronic enclosures divide into two families: those that must keep signals in or out, and those that must keep the environment out. Most real parts do both, and a drawn shell delivers that without a fabricated box and a tube of sealant.

  • Drawn boxes and cans. The standard enclosure for control modules, power supplies and terminal blocks, formed from one blank with an integral flange so the only openings are the ones you pierce. This painted steel deep drawn enclosure box with flanges is typical, with one flange serving as lid seat, gasket land and mounting face.
  • Shield cans and RF covers. Shallow cans, often two-part, that solder or clip to a PCB over a sensitive section. Wall thickness runs 0.2 to 0.5 mm, and flange flatness is what decides whether the can solders cleanly in reflow.
  • Connector shells and backshells. Drawn cylindrical or D-shaped shells carrying a circular connector, with a flange for panel mounting and a clamp region for the cable braid. Bore-to-flange concentricity is the controlling dimension.
  • Battery and capacitor cans. Deep, thin-walled cylinders drawn in multiple stages with intermediate annealing, where the closed end must stay free of thinning at the punch radius.
  • Instrument and meter housings. Shallow covers pierced with display windows and cable glands. Steel deep drawn cubic housings with top slots are common here, the slots doing double duty as convection venting and cable exit.
  • Field device housings. Rounded-corner aluminum enclosures for sensors and junction boxes. Rounded corners are not cosmetic: they remove the sharp internal corner where a folded box cracks under impact, and they shed water. This aluminum deep drawn enclosure with rounded corners shows the form.

Volume dictates the route. Below roughly two thousand units a year, a laser-cut and folded box is usually cheaper. Above that, the labour in a fabricated box overtakes the tooling amortisation in a drawn one, and drawing also holds a flange flatness that folding rarely achieves. We compare both at quotation rather than assuming one.

EMI and RFI Shielding Considerations

A drawn enclosure is inherently a better shield than a fabricated one, because shielding effectiveness is dominated by apertures and seams rather than by metal thickness. A folded box has four corner seams plus a lid joint; a drawn box has one lid joint, and that joint can be a continuous gasketed land.

Slot-shaped apertures are the usual culprit. A long vent slot radiates far more efficiently than a circle of the same area, so the remedy is to break one long slot into several short ones or into an array of round holes. As a working rule, round holes with a diameter well below a tenth of the wavelength of interest give the required airflow with far less leakage than an equivalent-area slot. Give us the highest frequency of concern and we will size the perforation pattern accordingly.

Material choice follows the frequency range. For low-frequency magnetic shielding, high-permeability alloys such as mu-metal are required, and because cold work degrades permeability these need a post-draw hydrogen anneal. At higher frequencies reflection dominates, so conductivity matters more and copper, aluminum or brass perform well. Cold rolled steel and stainless steel are less conductive but often adequate where the steel also provides strength; stainless steel is roughly an order of magnitude less conductive than copper, so where shielding is the primary function, aluminum is the better call.

Joints and finishes are where shielding designs fail. A painted or anodised flange is an insulating layer: bolt a lid onto a powder-coated face and the halves are not electrically continuous, turning the seam into a slot antenna. The remedies are masking a continuous bare metal contact band, fitting a conductive gasket, or specifying a thin chromate conversion coating that fastener pressure will displace. We mask contact bands as routine, provided the drawing calls them out.

Ingress Protection, Grounding and Finishes

IP ratings come from geometry and gasket design, and the drawn shell makes both easier. A continuous flat flange gives the gasket an uninterrupted land — no weld bead to bridge, no corner to leave a gap. Lids are retained with enough fasteners around the perimeter to keep compression even; uneven compression, not gasket material, is the most common cause of a failed IP6K or IP7 test.

Cable entries are the other frequent failure point. Glands need a flat, burr-free face to seal against, so we deburr or coiner-flatten gland seats after piercing. Where knockouts are used, we advise on minimum spacing from the flange edge, since a knockout too close to the wall deforms the flange when punched out.

Grounding has to be designed in rather than added later. We supply welded or pressed grounding studs, masked bare-metal pads for star washers, and tapped holes with tooth-lock washer seats; on painted enclosures the stud is fitted after coating or masked during it. If the enclosure carries a protective earth under IEC 60204 or a similar standard, tell us at quotation so stud size, thread and contact area are specified up front.

  • Powder coating. Default for industrial enclosures: polyester outdoors for UV stability, epoxy indoors for chemical resistance, at 60–120 µm with threads and grounding pads masked.
  • Zinc plating with chromate or trivalent passivation. Chosen where conductive contact matters, since a thin zinc layer stays conductive under fastener pressure.
  • Anodising on aluminum. Hard-wearing and corrosion resistant but insulating, so contact surfaces must be masked or machined after treatment.
  • Bare or passivated stainless steel. For food, medical and wash-down environments — 304 stainless steel for general use, 316 stainless steel for chloride exposure, passivated to remove free iron from the drawn surface.

If you are weighing a drawn, machined or fabricated enclosure, the trade-off is usually tooling cost against seam count. Our comparison of deep drawn vs machined vs welded housings covers the crossover points, and material selection for deep drawing gives draw limits for the alloys listed above.

Frequently Asked Questions

Can a drawn enclosure meet IP66 or IP67?

Yes, provided the joint is designed for it. A continuous drawn flange gives the gasket an uninterrupted land, and we specify fastener count and spacing to keep compression even. The rating is then verified by test on your assembly rather than assumed from the shell alone.

How do you keep EMI performance when the enclosure is painted?

By masking a continuous bare metal contact band on the mating flange so the lid and body stay electrically continuous, or by fitting a conductive gasket. Tell us where the band needs to be and we will mask it during coating.

Which material is best for a shield can at high frequency?

Aluminum or copper, because conductivity drives reflection loss at high frequency. Stainless steel is far less conductive and is chosen for strength or corrosion resistance rather than for shielding performance on its own.

Do you fit grounding studs and earth terminals?

Yes. We weld or press grounding studs, mask bare contact pads, and supply tapped holes with tooth-lock washer seats. Specify the thread and required fault current so the stud and contact area are sized correctly.

What is the minimum wall thickness you can draw for an enclosure?

About 0.2 mm for small shield cans in easy-to-draw alloys, and 0.5 to 1.5 mm for general industrial enclosures. Very thin walls limit flange flatness and thread engagement, so we confirm feasibility against the actual part size.

For the shielding, tolerance and material questions that sit behind these enclosures, the material selection guide covers the alloys used for EMI parts, and the LDR reference explains the depth limit per stage.

Explore More

Other industries we draw for: LED lighting · HVAC & refrigeration · automotive motor components · automotive · battery & energy storage · medical & healthcare · defense & optics · industrial enclosures · sensor & probe housings. See how we work in deep drawing, metal stamping and quality control.

Need a custom drawn electrical component? Send your drawing — quotation within 24 hours.

Request a Quote for This Part

Send a drawing or sketch — get material advice, tooling cost and a per-piece price within 24 hours (working days).