A capillary offered as stainless steel, copper or nickel is three different products with three different sets of properties, and the choice is not a matter of preference. It decides the temperature range, whether the capillary can carry a thermocouple, whether it can be bent to a tight radius, and what happens when the process is above 200 degrees.
Deep drawing followed by CNC finishing on critical faces, at +/-0.01 mm on sealing faces and +/-0.05 mm on drawn profiles. On a capillary that tolerance scheme is right, and it points at the fact that the tight band is on the ends – because on a capillary the ends are the seal and the tube is the requirement.
Nickel, copper and stainless steel, and they are not interchangeable
- Nickel is the alloy that survives what stainless steel does not: temperatures to around 600 degrees, caustic and some acid service, and a combination of strength and corrosion resistance that nothing else in this list matches. Its cost and its hardness are the penalties. So a nickel capillary is the answer when the process is hot or caustic, and it is usually the only one of the three that is.
- Copper conducts heat superbly and is easy to form, and it has two limits that decide its use. It is soft enough to be damaged by handling and by the process flow itself, and it oxidises. On a capillary that has to be routed tightly and repeatedly, copper’s formability is a genuine advantage and its durability is a genuine weakness.
- Stainless Steel – 304 or 316L – is the general answer. It is stiff enough to hold its shape, it resists ordinary corrosion, it is readily available, and on a moderate-temperature service in a benign fluid it is the cheapest correct answer.
- And the alloys differ from each other in ways that matter here. 304 versus 316L is the chloride question and it appears on every stainless steel page in this section. What is specific to a capillary is that 304 is more prone to work-hardening in the forming, so on a tube that will be bent repeatedly 304 is at a disadvantage relative to a tube made from a more formable grade.
Bendability, and why the alloy choice and the routing are the same decision
A capillary has to be routed, and the alloy decides how tightly.
- Stainless Steel bends with a radius proportional to its diameter, and a tube bent below its minimum radius kinks permanently. A kink is an ovality, and once oval the tube’s behaviour changes – its flow area, its flexibility, and on a leads capillary the position of the conductors inside it.
- Copper takes a much tighter radius and is therefore the better answer where the route is tight or where the capillary has to be formed at installation rather than supplied formed.
- Nickel is formable but springy, so a nickel capillary will take a bend and will try to spring back – which means that on a capillary that is clamped and expected to stay in a shape, the clamp has to hold a springy tube.
- So the minimum bend radius is a function of the alloy, and it has to be stated per alloy rather than once for the part. A drawing that gives one radius for a part that may be made in three alloys is under-specified in three different ways.
Which capillary can carry a thermocouple
Here the alloy choice stops being a mechanical decision and becomes an electrical one, and this is the point that gets missed on a capillary order.
- If the capillary carries leads, the tube must not touch them anywhere along their length. If it does – because the tube is pressed tight, or because the leads are in contact with the tube at a support – then the tube is in the measurement circuit and the arrangement must be designed for it. That means the tube has to be compatible with the thermocouple’s sheath material.
- Copper and nickel are both copper-family alloys and neither will normally be used on a grounded thermocouple. So a copper or nickel capillary carrying a thermocouple implies an ungrounded arrangement, and that is a specification rather than a detail.
- And there is a thermal argument. On a thermocouple capillary, a lower-conductivity tube flattens the temperature gradient along the tube and reduces the conduction error. Stainless Steel’s poor conductivity is therefore an advantage on a thermocouple and a disadvantage on a resistance thermometer, from exactly the same physics. That inversion is worth knowing before the material is chosen, because the intuitive answer – the good conductor is the better probe – is wrong in one of the two cases.
The finish of a capillary comes down to what the tube carries
Plating, coating or polishing to suit the drawing, with alternatives quoted alongside the quotation and samples approved in writing. On a capillary the finish is dominated by one question.
- What is in the tube? If it carries a fill or a process fluid, the interior has to be clean – free of oil, free of scale, free of any residue – and that is a cleaning requirement on the drawn and machined interior rather than a finish. On a nickel or copper tube this matters more than on stainless steel, because both are more reactive and both will show a contaminated interior.
- If it carries leads, the interior’s requirement is that it not abrade the conductors and that it be clean – a different requirement, and a general “clean” note covers neither.
- On the exterior, the finish is conventional corrosion protection with one extra consideration: on a capillary that will be bent and handled, a coating that cracks at the bend is a corrosion initiation site. So on a capillary the finish’s flexibility matters more than its appearance.
Tolerance, and where a capillary’s accuracy actually lives
+/-0.01 mm on sealing faces and +/-0.05 mm on drawn profiles, with critical dimensions carrying CMM data. That is correct for the ends and it leaves the tube at a general band, which is right – but on this part the requirements that matter most are not dimensions.
- Sealing faces at the tight band – the end that seals to the vessel or the instrument.
- The bore and wall at a general band, because on a drawn tube those are the material’s own variation and they are uniform enough along the length.
- And the four requirements that are not dimensions: the minimum bend radius for the specific alloy, the leak rate along the whole length, the tube’s interior’s cleanliness, and – if it carries a thermocouple – whether the arrangement is grounded or ungrounded. Those four determine whether the part works and none of them appears as a tolerance.
On a drawn tube, wall consistency along the length is the real risk
First articles verifying the whole flow before the run is released. On a capillary supplied in three possible alloys the inspection plan has to handle all three.
- Bore and wall at both ends and at the middle, where consistency along the length matters to the application – because on a drawn tube a mid-length check is genuinely informative.
- A bend test to the specified minimum radius on a sample, per alloy. This is a one-line check that verifies the material’s condition and its formability, and it catches the wrong temper immediately.
- A leak test along the length, where the tube is a pressure line. An end test on a long capillary proves nothing about the middle.
- Surface finish inspection internally where the tube carries a fill, because a contaminated interior in a nickel or copper tube will contaminate the fill.
- And material verification where the alloy is the distinguishing feature of the order – because three alloys of the same dimensions will behave differently and the customer needs to know which one arrived.
The process temperature and what is in the tube pick the alloy
What is the process temperature, and what is in the tube? Those two answers decide the alloy, and they are the two that nobody states on a capillary order. The temperature decides whether stainless steel is enough or whether nickel is required – and the jump from stainless steel to nickel is not a small step, it is the difference between a tube that costs a few cents a metre and one that costs several times that. The contents decide the interior’s requirement, and on a fill capillary the interior’s cleanliness is what makes the fill behave correctly. And there is a third question that belongs with them because it changes what the capillary is: does this capillary carry a thermocouple, and is the arrangement grounded or ungrounded? Because if it carries a thermocouple, then the capillary’s alloy is no longer only a mechanical and a corrosion decision – it is an electrical one, and it has to be compatible with the thermocouple’s sheath. A copper capillary carrying an ungrounded thermocouple is a legitimate and common combination. A copper capillary carrying a grounded one is a short circuit in the measurement. And that distinction is made at the enquiry and not at the assembly bench, because it changes the tube and the tolerance and the interior.
Parts like this one sit under the Sensor Housings range, whose overview page gathers the tooling logic, finishing options and tolerance notes shared across the family.
Specifications
| Item | Premium Stainless Steel Copper Nickel Capillary Tubes |
|---|---|
| Brand | AUNOV |
| Designing | Made to your 2D/3D drawings (PDF, DWG, STEP, IGS) – unusual walls, threads or tolerances are feasibility-checked first; the agreed version governs every later batch. |
| Tooling | Tooling is built to the drawing and held against your part number for the life of the part. |
| Samples | Pre-production samples come with a full inspection report, so the approved first article becomes the gauge reference, and production starts only after your written sign-off. |
| Materials | Materials held include carbon steel, 304 / 316 stainless steel, aluminium and brass; mill certificates and heat numbers accompany the first article. |
| Surface finish | Plating, coating or polishing to suit the drawing; alternatives quoted with the quotation, samples approved in writing. |
| Processing | After deep drawing, critical faces are CNC finished; the whole flow is verified on first articles before the run is released. |
| Equipment | Hydraulic drawing presses and CNC lathes for sealing faces, backed by CNC turning centres and a climate-controlled inspection room. |
| Tolerance | +/-0.01 mm on sealing faces, +/-0.05 mm on drawn profiles; critical dimensions carry CMM data with the shipment. |
| Delivery terms | FOB, CIF or DDP per Incoterms 2020, T/T or L/C, with D/P accepted on repeat business; price breaks tie to annual volume. |
Related Products
Frequently Asked Questions
Why are stainless steel, copper and nickel three different products?
The material decides temperature range, whether a thermocouple can be carried, whether it bends to a tight radius and what happens above 200 degrees, so the choice is functional, not preferential.
How are the ends held on these capillaries?
Sealing faces at the ends are finished to +/-0.01 mm and the drawn profile to +/-0.05 mm, with the tight band on the ends because the ends are the seal.
Can copper and nickel capillaries be bent tightly?
Copper and nickel take tighter bends than stainless steel for a given wall, but the bend radius is set against the wall so the capillary does not collapse or work-harden in the bend.
Does AUNOV anneal between operations?
In-line annealing is used where work-hardening would otherwise close the window, so the capillary keeps its ductility through the length.
Request a Quote for This Part
Send a drawing or sketch — get material advice, tooling cost and a per-piece price within 24 hours (working days).