Steel Deep Drawn Enclosure Box with Side Handles

Steel Deep Drawn Enclosure Box with Side Handles
Steel Deep Drawn Enclosure Box with Side Handles

A steel enclosure box with side handles: carrying weight and shielding electronics at once

Some enclosures sit on a wall and never move. This one is built for the opposite life: a steel deep drawn enclosure box with side handles is specified when equipment gets carried, dropped on bench tops, stacked in vehicles, and serviced in the field. The deep drawn body gives it a one-piece shell – no corner welds to crack, no seam lines to admit dust – and the side handles make the difference between equipment that travels safely and equipment that travels with a dent where the operator grabbed it.

The handles themselves are usually drawn or pierced as integral features where the design allows: a handle recess with a bridge is formed in the same stroke sequence as the body, so there is nothing to tear off. Where the handle must carry real load, a steel handle is welded inside the recess – and because the recess is formed, the handle sits flush inside the box outline and does not snag on racks or shelves.

The body: what deep drawing contributes to an enclosure

A fabricated enclosure starts as five panels and four welds. A drawn enclosure starts as one blank. The practical consequences:

  • No corner seams. Dust and drip paths through welded corners are the number-one field failure of fabricated boxes. Drawn corners are continuous metal with a radius, typically 3-8 mm inside.
  • Controlled stiffness. The drawing operation work-hardens the steel, and the wall can be varied by design – thicker at the base where it meets the mounting flange, thinner in the sides.
  • Clean EMI behaviour. A seam-free steel box with a gasketed lid is a natural shield; a welded box’s seams are impedance surprises. For electronics housings, drawn steel plus conductive gasket routinely reaches shielding levels fabricated boxes chase with finger stock.
  • Repeatable appearance. The visible surfaces come out of the die identically, batch after batch – important if the enclosure is customer-facing.

Size and construction envelope

On our presses, drawn steel enclosure boxes run from 60 mm cube up to about 400 mm on the longest side, with depth-to-width ratios up to roughly 1:1 in one draw and deeper boxes built as a drawn body plus a drawn or stamped lid. Wall thickness 0.8-2.0 mm in SPCC or DC01; 304 stainless steel for wash-down and corrosive environments. Boxes deeper than one draw allows are redrawn, and handles or recesses are pierced and formed after the body reaches final form so their positions lock to the machined or printed datums.

Mounting flanges, gasket faces, gland-plate holes and lid screw bosses are all planned at RFQ stage – the difference between a smooth program and a patched one is almost always how early those features were discussed against the drawing sequence.

Handles: formed, welded, or folded – the trade-offs

  • Formed handle recess with bridge (fully integral): nothing to add, cheapest at volume, carries light loads – right for small instruments and test devices.
  • Steel bar handle welded into the recess: carries 20-50 kg per pair comfortably; the weld is inside the recess so the outside stays clean and flush. Our standard for portable equipment and field instruments.
  • Folded sheet handle on the flange: a middle path – formed from the flange itself, no added parts, loads between the two above.

Handle load ratings are not guesswork: pull tests to your stated handling load (typically 4× safety factor) are part of first-article validation.

Corrosion protection and finish

SPCC boxes leave the press ready for finish: e-coat as the base layer (it reaches inside corners spray never does), powder coat on top for colour and impact resistance – a combination that survives salt-spray testing past 500 hours. 304 stainless steel versions are passivated or bead-blasted for wash-down duty. EMI-shielding builds keep the flange contact surfaces bare or conductive-finished so the gasket does its job – paint on a gasket face is the classic self-inflicted shielding failure, and our finish drawings call those zones out explicitly.

Tolerances and validation

  • Body OD ±0.5 mm as-drawn; lid-to-box flange fit designed with 0.3-0.5 mm clearance so assembly never fights tolerance stack.
  • Flange flatness 0.5 mm per 200 mm, improved by coining where a gasket sits.
  • Pierced gland and connector holes ±0.2 mm position; machined features ±0.05 mm.
  • Validation on first articles: dimensional layout, gasket-compression check with the actual lid, handle pull test, and salt-spray or IP-code support testing on request (IP54 achieved with a drawn box plus compressed gasket is routine; we state the boundary honestly rather than promise IP67 from a design that cannot reach it).

Where these boxes are working

  • Portable test and measurement instruments – drawn steel body, welded side handles, powder-coated, e-coat underneath.
  • Field control units and junction enclosures in 304 for wash-down food and chemical plants.
  • Broadcast and comms transport cases where EMI shielding and drop-survivability both matter.
  • Medical carts and point-of-care units – seam-free corners for wipe-down hygiene, handles for room-to-room moves.

Questions we are asked about drawn steel enclosures

Can you add internal mounting bosses without welding?

Usually yes – pierced and lanced bosses or PEM-style inserts pressed in after drawing cover most board and rail mounting needs. Welded studs are the fallback and are done in-house.

What is the largest single-drawn box you can make?

Around 400 mm on the longest side in 1.0-1.5 mm steel on the 500 T hydraulic press; larger boxes are practical as a drawn body plus drawn lid, and the quotation will show that split rather than overpromise one stroke.

Do the handles meet a specific pull standard?

We test to your stated handling load with a 4× factor as standard, and to specific standards (IEC, MIL-STD drop/handle clauses) when the program calls for it – name the standard at RFQ and it goes into the control plan.

What we need to reverse-engineer an enclosure

Send the enclosure drawing or an existing box to reverse-engineer, plus what it must carry, where it operates, and the handling expectation. The quotation comes back with the die sequence, handle construction recommendation, finish system and validation plan – the whole engineering picture, before tooling commitment.

Not sure whether to draw, machine or weld this geometry? The guide to deep drawn covers compares the three routes and shows where each one wins; the full Precision Deep Drawn Parts range is linked from the overview page.

Specifications

ItemSteel Deep Drawn Enclosure Box with Side Handles
BrandAUNOV
DesigningA drawing file or a physical sample starts the review, the quotation comes back with a manufacturability review attached.
ToolingTooling designed and cut in house, each die held against your part number.
SamplesThe first-article set ships with dimensional data and material certification.
MaterialsCarbon steel (SPCC / DC01) leads the stock list for this part, alongside 304 / 316 stainless steel, aluminium, brass and copper, per the drawing.
Surface finishThe drawing requirement picks between zinc, nickel or chrome plating, e-coat, powder coat, anodising and passivation.
ProcessingStaged deep drawing, with in-line annealing where the draw ratio requires, pierced and machined on the same floor.
EquipmentPresses run 5-250 T mechanical and 250-500 T hydraulic, with CNC turning centres and a climate-controlled CMM room for inspection.
ToleranceDrawn tolerances held to +/-0.1 mm, +/-0.03 mm after machining.
Delivery termsStandard terms FOB, DDP offered to EU and US, T/T and L/C accepted, D/P for established customers, call-off schedules and blanket orders supported.

Request a Quote for This Part

Send a drawing or sketch — get material advice, tooling cost and a per-piece price within 24 hours (working days).