Plain Round Sensor Sleeve Tube, Open-End

Plain Round Sensor Sleeve Tube, Open-End
Plain Round Sensor Sleeve Tube, Open-End

A plain round sensor sleeve tube, open-end, is a straight drawn tube of circular cross-section with no closed end – a protective sleeve the sensing element or its lead passes through. Being open at both ends, it slides over a probe or cable run instead of enclosing it, which is what makes it a sleeve rather than a housing. Its whole behaviour is set by the diameter, the wall, and how straight and round the drawn bore holds.

A 6 mm diameter with 50 mm of length is a slenderness of about eight to one. That is enough that the part’s behaviour is dominated by three things a short housing would not have: conduction along the wall, bending at the mounting end, and the fact that the response is a function of mass rather than of surface.

Why the length is the specification

On a temperature sensor the length is not a size, it is a design decision with three consequences, and they all point the same way.

  • Conduction along the wall. The tip sees the process temperature. The mounting end sees whatever is at the other end. The heat conducts along the 50 mm of steel between them, and the sensor reads somewhere between the two – closer to the tip than to the base, but measurably displaced by the base. This is the dominant error on any long insertion probe and it scales with the length.
  • The usable insertion depth. If the housing enters the process 20 mm, then 30 mm of it is outside, conducting heat from the ambient toward the tip and pulling the reading down. If it enters 45 mm, almost all of it is in the process and the reading is much closer to true. So the required length and the required insertion are the same number argued from two directions, and the drawing needs both.
  • Mass, and therefore response. A long thin housing is a large mass of metal, and a large mass is a slow sensor. The time constant scales with the mass and inversely with the surface area, so for a given diameter, doubling the length roughly doubles the response time. On a fast process, a long probe is unusable, and this is a genuine trade rather than a deficiency.

So the very first question is: what does the process temperature do over time, and how fast does the reading have to follow it? A tank temperature, a furnace, a bearing, a food product during a cooking cycle, an engine’s coolant – each of these wants a completely different answer, and the answer sets the length and the diameter together.

Conduction error, and the fix that is a drawing decision

Since the conduction error is the dominant one and it scales with length, the useful question is whether it can be reduced geometrically. It can, and three ways.

  • Insulate the exposed length. If part of the probe is outside the process, covering that length reduces the heat that flows along the wall from the ambient. This is a standard and effective measure on a long probe, and it is a drawing change – a sleeve, a coating, a reduced diameter on the exposed section.
  • Reduce the diameter. Conduction along the wall scales with the cross-sectional area, so halving the diameter roughly halves the conduction. A thin long probe conducts less than a thick long probe of the same length. This is the reason many immersion probes are 3 mm or 6 mm rather than 12 mm, and it is the reason this one is 6.
  • And accept it, then quantify it. On a slow process the conduction error is constant, small, and easily calibrated out. The important thing is that it is known: a probe with a stated and accepted conduction error is a good instrument, and a probe with an unquantified one is not.

Wall thickness and the closed end, on a drawn part

Stainless Steel 304 and 316L, pickled and annealed, with the grade chosen for the corrosion duty and for formability. The tube is deep drawn and one end is closed, so both of the mechanisms that apply to a drawn sensor housing apply here, and on a long thin tube the wall’s uniformity matters more.

  • The blank’s thickness is the specification, and on a long tube a small variation in wall thickness is a visible variation in response. A tube whose wall varies along its length will have a response that varies along its length, and that is a real and measurable defect.
  • The closed end is thinner than the nominal wall. The punch nose stretches the metal, and on a probe where the closed end is the sensing surface, the thinning lands exactly where the accuracy is decided. A minimum wall at the closed end is a real specification.
  • And the closed end’s thickness is a stiffness question too. A thin closed end deflects under handling and under the insertion force, and a dented tip is a permanently wrong probe.

The stepped bore, and why it is the tight dimension

+/-0.03 mm on stepped bores, with concentricity per the print and GD&T per drawing. That tight band sits on the stepped bore and nowhere else, and here is why: a stepped bore in a probe is a locating feature and a thermal isolation feature at the same time.

  • It locates. If a lead, a terminal, or an element assembly is crimped or bonded into that bore, then the bore’s diameter and roundness determine where the internal assembly sits, and its concentricity to the tube’s axis determines whether the internal assembly is on the probe’s centreline. A mispositioned internal assembly is both a thermal error and a mechanical one.
  • It isolates. A step in the bore creates a dead volume between the element and the mounting end, and that dead volume is thermal mass that has to heat up before the reading stabilises. The depth of the step is a response-time decision as well as a geometry one.
  • Its position sets the assembly depth, which is what sets how much of the probe’s length is active.

So on this part the stepped bore deserves the tight band, the concentricity callout, and a stated internal finish – and everything else on the tube can be held at the general band.

Corrosion, and the specific case of immersion probes

304 and 316L, pickled and annealed. On a probe the grade is decided by the process fluid and by the cleaning regime, and there are two immersion-specific points worth raising.

  • Chloride in a warm process. Chloride pitting resistance falls sharply above about 60 degrees, and a probe in a warm chloride-bearing process is a harder case than the same probe in a cold one. Where the process is warm and chloride-bearing, a stainless steel probe may not be the right answer and the fluid’s temperature as well as its chemistry needs to be stated.
  • Crevice corrosion at the mounting end. The junction between the probe and the mounting hardware is a crevice, and if the process can reach it the probe will corrode there. The sealing of the mounting end is a real requirement and it is the one that gets forgotten, because the sensing end is what everyone thinks about.
  • Where the process is a food or a pharmaceutical product, the grade’s surface condition is a documented requirement, and the passivation record is part of the deliverable rather than a detail.

The sensing tip is the product, and it has to stay bare

Plating, powder coating, anodising or polishing per the print, with alternatives quoted with the quotation and samples approved in writing. On a probe the finish has one dominant requirement and three smaller ones.

  • The sensing tip is the product and it must be clean. The tip’s surface is what touches the process, and on a food or a pharmaceutical application it is a documented, inspected surface. It is not plated, and it is not coated, and it is usually drawn and annealed – which is why “pickled and annealed” in the material specification is doing real work.
  • Any sealing face at the mounting end, unmasked.
  • Threads, masked or specified post-finish with an allowance. On a small probe thread the coating is a significant fraction of the pitch.
  • External appearance, where the probe is visible. A probe on a tank or a pipe is visible in a way that a buried fitting is not, and a polished or a satin finish on the exposed length is a normal expectation. It should be specified with a sample rather than by name.

State the insertion depth separately from the overall length

  1. The insertion depth required in service – not the overall length. These are different numbers and the drawing needs both, because the gap between them is what causes the conduction error.
  2. The insertion depth at which the accuracy claim is valid, stated separately from the physical length.
  3. The required response, or the process’s time scale. This is what determines whether 50 mm of 6 mm tube is the right answer or whether the probe should be shorter and thicker.
  4. The wall’s nominal thickness and tolerance, and the minimum wall at the closed end.
  5. The stepped bore’s diameter, depth and concentricity to the tube’s axis, and its internal finish.
  6. The mounting end’s arrangement – thread, flange, cable entry, or a mounting nut – and its sealing method.
  7. Whether the exposed length is insulated and if so how.
  8. The grade, and the process fluid and its temperature and chloride content as the reason for it.

A steady temperature in clean water wants a long probe and a slow response

What is the process temperature doing over time, and what fluid is it in? Everything on this page comes from those two answers. A steady temperature in clean water wants a long probe for accuracy and can afford a slow response. A fast-changing temperature in a viscous or a fouling product wants a short, thick, fast probe and it will accept a worse steady-state accuracy. A temperature in a salty process at 80 degrees wants a different grade or a different material altogether, and a probe in a food application wants documented surface condition and passivation records as a deliverable. Eight answers would go on the drawing and two of them decide the rest. Asking those two before the enquiry is quoted costs a sentence and it occasionally saves the whole probe, because the wrong answer here is not a tolerance problem – it is a probe that reads correctly and slowly, or fast and wrongly, and neither of those is discovered until the process is running.

This part belongs to our Sensor Housings range. The sensor housings pages collect the process notes, common materials and inspection points behind every product in the family.

Specifications

ItemPlain Round Sensor Sleeve Tube, Open-End
BrandAUNOV
DesigningYour drawing sets the part – a manufacturability review comes back with the quotation; revisions are re-quoted once rather than silently absorbed.
ToolingOur toolroom covers die design, wire-cut EDM and maintenance, so no tooling step is outsourced, and ownership is confirmed on the quotation.
SamplesSamples are issued for approval before the run, so the approved first article becomes the gauge reference, and the signed sample is kept for future reorders.
MaterialsStainless Steel 304 and 316L, pickled and annealed, 50 mm nominal wall – one grade chosen for corrosion duty and formability of this sensor.
Surface finishPlating, powder coating, anodising or polishing, per the print; alternatives quoted with the quotation, samples approved in writing.
ProcessingDeep drawing followed by CNC finishing on critical faces; first articles verify the whole flow before the run is released.
EquipmentHydraulic presses for drawing, with CNC turning for finishing; secondary ops run on CNC turning centres, inspection on the CMM.
Tolerance+/-0.03 mm on stepped bores, concentricity per print; GD&T per drawing, PPAP-style reports on request.
Delivery termsFOB, with DDP offered for EU and US addresses, payment by T/T, L/C at sight or D/P; repeat orders reuse the approved first article.

Frequently Asked Questions

Why is the length the real specification on this probe?

The 6 mm diameter and 50 mm length give a slenderness near eight to one, so the behaviour is dominated by conduction along the wall, bending at the mounting end, and a response that scales with mass. The required insertion depth and the overall length are the same number argued two ways, and both belong on the drawing.

How is the conduction error – the dominant one – actually reduced?

Three ways, all drawing decisions: insulate the exposed length, reduce the diameter because conduction scales with cross-sectional area, or accept and quantify it on a slow process. Accepting and quantifying the conduction error beats leaving it unknown, because a probe with a stated error is a good instrument and one with an unquantified error is not.

Why is the stepped bore the tight dimension at +/-0.03 mm?

The stepped bore locates the element or terminal and isolates a dead volume that is thermal mass, so its diameter, roundness and concentricity to the axis decide both the assembly position and the response time. Everything else on the tube sits at the general band, and the bore gets the tight one plus a stated internal finish.

Why must the sensing tip stay bare?

The closed end is the sensing surface, and plating, coating or polishing it would change the thermal contact and the documented surface a food or pharmaceutical application requires. On a probe the finish has one dominant rule – the tip stays unmasked while the threads and faces are masked – because the tip is what touches the process.