A stainless steel multi-step drawn sensor sleeve is a tube whose diameter changes in two or more steps along its length, each step seating a different part of the assembly. The steps are what let one sleeve locate the element, the seal and the connector in sequence without extra components. Every step is a draw followed by a sizing pass, and the bore has to stay concentric through all of them or the element will not drop in cleanly.
Drawn shell with machined seats and threads where the print calls for them, at +/-0.03 mm on stepped bores and concentricity per print, with dimensional reports accompanying the first article. So the tight band is on the bores – and on a thermostat probe, the bore is not the feature that matters. The wiring is.
Two-wire, three-wire and what each one does to the housing
- Two-wire. The leads’ resistance is in series with the element’s, so the leads appear directly as a measurement error. For a thermostat this is often acceptable – a domestic thermostat’s accuracy requirement is a degree or two, not a tenth – but it means the probe’s accuracy depends on the lead length and the lead gauge, which are the installation’s decisions and not the probe’s.
- Three-wire. A third wire measures the lead resistance so it can be compensated. It is the usual choice on a thermostat because it costs one wire and removes the lead-resistance error, and it puts a requirement on the housing: three terminals or three sealed leads.
- And the housing’s role is to carry the leads out and seal around them, which is a different requirement at two wires and at three, because three leads through one small gland is a larger hole and a harder seal.
So the first question is: how many leads, and does the thermostat compensate? Because if it does not compensate, the lead resistance has to be in the probe’s specification – which means the probe and the lead set have to be specified as a pair, and that is not how thermostat probes are usually bought.
Grounding, and the safety question under a thermostat
On a thermostat used on a mains-powered appliance the probe sits in water, often at a temperature and in a position where it is reachable, and that raises requirements that are electrical as well as thermal.
- Is the probe insulated from the appliance’s earth? In most modern appliances the probe is fully insulated – the element is inside the thermowell and the leads are insulated and sealed. In older or cheaper ones the sheath is earthed, which gives the case a ground reference and can produce an offset error if the earth path changes.
- And the seal’s dielectric requirement. On an insulated probe the seal has to hold a dielectric strength, not just a pressure. That is a different test from a leak test, and on a plastic thermostat probe it is often the electrical test that actually matters.
- And where the probe is metal, whether it is grounded changes how the part is finished – and a passivated stainless steel probe is a poor earth path, which is either a feature or a problem depending on the design.
The bores, and why a thermostat probe’s accuracy is not about its metal
At +/-0.03 mm on the stepped bores the tight band is modest compared with the machined parts elsewhere in this section, and on a thermostat probe that is correct rather than a compromise. A thermostat’s accuracy requirement is coarse by instrument standards, so the money is better spent elsewhere.
- The element’s position in the bore is what sets the response, and a general tolerance on the bore is adequate as long as the position of the element within it is controlled by the assembly rather than by the bore’s size.
- What does need control is the seal’s compression, because a thermostat probe that leaks into its own electronics is a failed probe – and on a plastic housing the overmoulded or potted seal is what holds it.
- And on a thermostat probe the bore’s diameter is often the moulding or potting’s parameter rather than the machining’s, so the tight band’s destination depends on how the part is built.
Response time, which is what a thermostat actually buys
A thermostat is a switching device, and what a customer notices about a probe is how fast it reacts – not its absolute accuracy. That inverts the usual priorities and it is worth stating because it changes what to specify.
- A thermostat probe wants to be fast, which means low thermal mass, which means a small element and a thin housing. On a probe that is moulded in plastic, the plastic is the thermal mass and the plastic’s thickness dominates the response.
- And a fast probe is a fragile one. A thin plastic probe in a hot liquid can crack, and a thin metal probe can corrode through. So the response requirement is in tension with the durability requirement, and on a thermostat probe that tension is usually resolved by accepting a slightly slower, more robust probe – because a thermostat that fails closed is a nuisance and one that fails open is a hazard.
- Which raises the failure-mode question, and it is the one that matters on this part. A thermostat probe fails either open – no heating, which is visible – or closed – heating that cannot be switched off, which in a water appliance is a scald hazard. So the design should fail in the visible direction, and where a choice exists between a probe that is slightly slower and one that is slightly more fragile, the slower one is the correct answer.
Material, and where a thermostat probe differs from an instrument probe
Carbon steel, 304 and 316 stainless steel, aluminium and brass, with mill certificates and heat numbers on the first article. On a thermostat probe the material is usually not a free choice because the appliance’s own material and the water it sits in often decide it.
- 304 or 316L for a metal probe in water, on the usual chloride logic, and 316L where the water is hard or chlorinated.
- Plastics dominate this application for a good reason – low thermal mass, no corrosion, mouldable in volume – and where the probe is plastic the requirements are entirely different: the material’s thermal conductivity, its creep at temperature, and its ability to be moulded around the element and the leads. Those are not questions the metal pages answer.
- And the galvanic question, which on a thermostat is a specific and commonly-missed one. A metal probe in a metal appliance – a stainless steel probe in an aluminium tank, or a brass probe in a steel tank – is a galvanic couple in warm water with dissolved salts, and the probe’s area is small but the appliance’s is large. So the probe’s material can be partly dictated by the appliance’s, and on a stainless steel appliance a brass probe is not always the answer.
Where leads are potted, the surface they enter has to be prepared
Deep drawing presses plus CNC turning centres, with in-house toolmaking. On a thermostat probe the finish’s main requirement is usually not corrosion but appearance and the seal’s adhesion.
- Where the leads are potted or overmoulded, the surface they enter has to be clean and bondable, which on a drawn shell is a masking or a cleaning requirement.
- Where the probe is visible – inside a fridge, or on a display housing – the exterior’s finish is an appearance requirement and an approved sample is the specification.
- And on a metal probe in a wet environment, passivation is the finish on stainless steel and it should not be confused with a plating – a plated probe in an appliance will have its plating breached at a scratch and then corrode behind it.
A thermostat probe’s real requirements sit outside the dimensional scheme
+/-0.03 mm on stepped bores and concentricity per print. On a thermostat probe the dimensional scheme is modest and the requirements that carry the part are elsewhere.
- Bore diameter and the element’s seat, to the general band.
- Any thread or lead exit, if present.
- And the requirements that are not dimensions: the number of leads, whether the probe is grounded or insulated, the dielectric requirement if it is insulated, the response time, and the failure mode – open or closed. Those five determine what the part is, and on a thermostat probe they are all missing more often than any dimension is.
Two-wire or three-wire, and grounded or fully insulated?
Is this probe wired two-wire or three-wire, and is it grounded or fully insulated? Two questions that decide whether the housing needs three sealed leads or two, whether the seal has to hold a dielectric strength or only a pressure, and whether the thermostat is going to compensate for the lead resistance. And then there is the question that is the one that matters most on this part and that is almost never asked: what happens when this probe fails – open or closed? Because on a thermostat the failure mode is a safety property rather than a performance one. A probe that fails open means no heat and a visible symptom. A probe that fails closed means continuous heating in a water appliance, which is a scald hazard and a product-liability question. So if the design has a choice between a faster and more fragile probe and a slower and more robust one, the answer should be the robust one, and where the probe’s construction can be arranged so that the failure is open, that is worth doing deliberately. It costs nothing on the drawing and it is the difference between a complaint and a recall.
This part sits inside our Sensor Housings range. Across the sensor housings pages you will find the process notes, common materials and inspection points behind every product in the family.
Specifications
| Item | Stainless Steel Multi-Step Drawn Sensor Sleeve |
|---|---|
| Brand | AUNOV |
| Designing | DFM feedback accompanies the quotation, so surprises are caught before the die is cut. |
| Tooling | Progressive and drawing dies are designed and built in house, so the die charge appears as its own quotation line, and the charge is refundable against agreed volumes. |
| Samples | Sample lead time is quoted with the order, and the approved sample governs the run. |
| Materials | Carbon steel (SPCC / DC01), 304 / 316 stainless steel, aluminium and brass are held on site; mill certificates and heat numbers accompany the first article. |
| Surface finish | Zinc, nickel or chrome plating, anodising, passivation or e-coat; alternatives quoted with the quotation, samples approved in writing. |
| Processing | Where the print calls for them, seats and threads are machined into the drawn shell; batch records on file mean repeat orders start from approved data. |
| Equipment | Deep drawing presses plus CNC turning centres for machined faces, with in-house toolmaking to keep dies and fixtures maintained. |
| Tolerance | +/-0.03 mm on stepped bores, concentricity per print; dimensional reports accompany the first article. |
| Delivery terms | FOB, CIF or DDP per Incoterms 2020, payment by T/T or L/C, quoted in USD or EUR; each volume tier carries its own quoted price. |
Related Products
Frequently Asked Questions
Why is the electrical specification the missing one on a thermostat probe?
How the probe is wired is a design decision that changes the probe, and it is decided by the thermostat rather than by the probe’s maker. Two-wire or three-wire, and grounded or fully insulated, is the question that drives everything else on this page. Drawn shell with machined seats and threads where the print calls for them runs at +/-0.03 mm on stepped bores and concentricity per print, with dimensional reports accompanying the first article.
Why is the bore not the feature that matters here?
At +/-0.03 mm on the stepped bores the tight band is modest compared with the machined parts elsewhere, and on a thermostat probe that is correct rather than a compromise. A thermostat probe’s real requirements sit outside the dimensional scheme: grounding, the safety question under a thermostat, and response time. Response time is what a thermostat actually buys.
Where the leads are potted, what has to be prepared?
Where leads are potted, the surface they enter has to be prepared, or the potting will not hold and moisture will track the lead. Carbon steel, 304 and 316 stainless steel, aluminium and brass are held, with mill certificates and heat numbers on the first article. The material question differs on a thermostat probe from an instrument probe because the duty is different.
Two-wire or three-wire, and grounded or fully insulated?
That pair of answers decides the lead count, the grounding scheme and the safety case, and it is decided by the thermostat. Deep drawing presses plus CNC turning centres, with in-house toolmaking, produce the part. Asking it at enquiry is cheaper than discovering the wiring after the housing exists.