Blind-Hole Sensor Housing

Blind-Hole Sensor Housing

304 stainless steel pressure/temperature sensor shell — one draw plus ironing.

Direct answer: AUNOV draws this 304 stainless steel sensor housing in a single draw on a 200 T press, then irons the wall from 0.8 mm to 0.62 mm to hold ±0.05 mm, with a sealed blind bottom that leaves no leak path.
Material304 stainless steel
Draw depth62 mm
Wall thickness0.8 → 0.62 mm (ironed)
Tolerance±0.05 mm
Press200 T
Forming routeSingle draw + ironing
Measured LDR1.85–2.05

The challenge

The part is a blind-hole shell: the bottom must seal with no leak path for a pressure sensor, the wall must stay uniform so the body can be welded or crimped to a fitting, and the outside diameter cannot drift or the seal geometry fails. A drawn wall that varies by a few hundredths is enough to make the weld fixture reject the part.

The blind bottom is formed as one piece with the wall, so there is no welded seam to leak — but that also means the bottom radius has to be set in the same stroke as the wall, which is why the die radius and punch profile are tuned to this 304 coil rather than a generic set.

Downstream, the housing is welded or crimped to a fitting and the open end often carries a connector, so the outside diameter and the wall at the joint have to be exact. The draw and iron is set so the seal geometry lands where the mating part expects it.

How AUNOV draws it

The 200 T press gives enough capacity to draw the 62 mm depth in a single stroke while controlling the bottom radius, and the ironing pass that follows sets the wall without touching the sealed bottom.

  1. Blank sized from the measured 304 limiting draw ratio (1.85–2.05) rather than a generic cup formula
  2. Single draw on a 200 T press, with die radius set for the 62 mm depth
  3. Ironing pass to bring the wall from 0.8 mm to 0.62 mm and set the wall tolerance
  4. CMM first-article check on diameter, depth and wall uniformity before release

Process control and inspection

A CMM first-article checks diameter, depth and wall uniformity, then we sample those same points through the lot, because a welded or crimped fitting depends on the wall landing in the same place every time.

The sealed blind bottom is verified by a pressure test on the first article, since the whole point is that there is no weld seam to leak; we confirm the bottom radius holds before release.

What this means for your part

If your sensor housing is a blind-drawn stainless steel shell in this size class, the 304 route above is already proven in production. Tell us the seal or weld interface and we size the wall and bottom radius to suit it.

For production we run a CMM first-article on diameter, depth and wall uniformity, then sample those same points through the lot so a welded or crimped fitting keeps seating the same way every time.

  • Tell us the seal or weld interface; the wall and bottom radius are sized to it.
  • Keep the outside diameter as a controlled feature, because the seal geometry fails if it drifts.
  • If a connector passes through the open end, give its position so we hold the wall there.

Frequently asked questions

Can a blind-hole sensor housing be deep drawn without a welded bottom?

Direct answer: Yes. The blind bottom is formed in the same draw as the wall, so there is no weld seam to leak. AUNOV draws the shell in one hit and then irons the wall to the required tolerance, which keeps the bottom and wall as one continuous piece.

What wall tolerance can a drawn sensor housing hold?

Direct answer: AUNOV holds ±0.05 mm on the drawn diameter and wall, and ±0.02 mm after ironing. The ironing pass is what sets the tighter wall, rather than relying on the draw alone.

Why draw a sensor housing on a 200 T press?

Direct answer: The 200 T press gives the capacity to form the 62 mm blind depth and the bottom radius in a single stroke while keeping the wall controlled. AUNOV then irons the wall to 0.62 mm, so the sealed bottom and the uniform wall are set in two controlled steps rather than one uncertain one.

Have a similar part?

Send the drawing and material — AUNOV returns a DFM review and a quote within 24 hours.

Request a quote

Sources Behind These Examples

Each example is built on measured material data and the process taxonomy set out by these standards. We keep the lot data behind each part on file for first-article review.

  • ASTM E646 — Standard Test Method for Tensile Strain-Hardening Exponents (n) of Metallic Sheet Materials. The n-value sets how much a wall can thin before necking.
  • DIN 8584 — Manufacturing processes, forming: classification of deep drawing operations and their subgroups.
  • ISO 20482 — Metallic materials: Erichsen cupping test, a formability measure complementary to LDR.
  • Wikipedia: Anisotropy — explains the r-value and why earing directions form.
  • Wikipedia: Work hardening — why redraws and intermediate annealing matter.

Similar Posts

  • Precision NTC Ring Terminal

    Precision NTC Ring Terminal SUS304 ring terminal for a European NTC temperature-sensor programme — anonymised PPAP summary. Direct answer: AUNOV produces this 0.25 mm SUS304 ring terminal with a Ø3.2 mm mounting hole on an eight-step route — blanking, stamping, punching, four-hour vibratory polishing, then 100% appearance and sampled dimensional inspection. The PPAP first article passed all…

  • Hinged Military Case

    Hinged Military Case Zinc-plated DC04 rectangular draw with a formed hinge flange. Direct answer: AUNOV draws this DC04 steel military case as a rectangular shell to 90 mm depth and 1.2 mm wall, then restrikes to hold flange flatness for the lid seal, sized from the measured DC04 limiting draw ratio of 2.1–2.2. Material DC04 steel Draw…

  • Prismatic Cell Can

    Prismatic Cell Can 5052 aluminium battery can — 0.15 mm wall, multi-stage draw. Direct answer: AUNOV draws 5052 aluminium prismatic cell cans to a 0.15 mm wall and up to 110 mm depth using multi-stage drawing with inter-stage annealing, sized from the measured 5052 limiting draw ratio of 1.80–1.95. Material 5052 aluminium Wall thickness 0.15 mm Draw depth…

  • EMI Shield Can

    EMI Shield Can Thin 5052 aluminium shield with fine walls and formed tabs. Direct answer: AUNOV produces this 5052 aluminium EMI shield as a shallow draw to 8 mm depth and 0.2 mm wall, pierced in the same tool, holding ±0.05 mm with no spring-back mismatch across the walls. Material 5052 aluminium Wall thickness 0.2 mm Draw depth…

  • Deep Drawn Part Application Examples

    Deep Drawn Part Application Examples Representative deep-drawn components we produce across automotive, battery, medical, defense and electronics — with the real forming envelopes we hold in production. Direct answer: AUNOV routinely deep-draws cylindrical and rectangular shells from 0.15 mm to 3.0 mm wall, up to 150 mm draw depth, at ±0.05 mm (ironing ±0.02 mm), on 5–500 T presses, with measured…